Pump and Motor Sizing Tool
Horsepower, shaft speed, and hot-liquid limits for Wanner Hydra-Cell Pro® pumps. Equations match the FDPP worksheet and the 2026 Wanner datasheets.
1. Duty
2. Pump and cam
3. Motor you plan to install
The recommended frame follows the drive and the liquid temperature. Above 160°F the cap is on duty horsepower, not the nameplate.
Maximum pressure at this motor
—
Send this sizing
Opens your email to [email protected] with the results, your notes, and a proposal request. Nothing is stored on a server.
Hot-liquid horsepower chart
Caps are applied horsepower (duty HPr), not the motor nameplate. Above 160°F without an oil cooler, stay at or under the right-hand number. With a cooler, or at 160°F and below, use the left-hand number. Source: FDPP high-temperature motor sizing article.
| Model | ≤160°F or with cooler | Above 160°F, no cooler |
|---|---|---|
| F20/F21 | Call FDPP | Call FDPP |
| M03/D03 | 2.3 HP | 0.8 HP |
| D04 | 5.3 HP | 1.7 HP |
| D10/M10/D12 | 6.5 HP | 2.1 HP |
| D15/D17 | 20.1 HP | 6.6 HP |
| H25 | 15.3 HP | 5 HP |
| D35 | 29.8 HP | 9.8 HP |
| D40 | Call FDPP | Call FDPP |
| D66 | 44.4 HP | 14.7 HP |
| T100 | 98.7 HP | 49.3 HP |
| Q155 | 161 HP | 80.5 HP |
| T200 | 203 HP | 101.5 HP |
| Q330 | 330 HP | 165 HP |